250 Gal Above Ground Propane Tank

General Specifications


  • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1.

  • Complies with NFPA 58.

  •  Rated at 250 psig from -20° F to 125° F. All vessels registered with National Board. All standard vessels UL listed (UL 644 – Container Assemblies for LP-Gas). Standard vessels available with CRN (Canadian Registration Number).

  •  Vessels are either powder coated with TGIC polyester or primed with liquid epoxy and coated with liquid urethane top coat.

  •  All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel.

  •  

333-250AG

More Info

UOM : EA

120 Gal Above Ground Propane Tank

General Specifications


  • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1.

  • Complies with NFPA 58.

  •  Rated at 250 psig from -20° F to 125° F. All vessels registered with National Board. All standard vessels UL listed (UL 644 – Container Assemblies for LP-Gas). Standard vessels available with CRN (Canadian Registration Number).

  •  Vessels are either powder coated with TGIC polyester or primed with liquid epoxy and coated with liquid urethane top coat.

  •  All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel.

  •  

333-120AG

More Info

UOM : EA

1000 Gal Underground Propane Tank

General Specifications


  • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1.

  • Complies with NFPA 58.

  • Rated at 250 psig from -20° F to 125° F. All vessels registered with National Board. Some standard vessels available with CRN (Canadian Registration Number).

  • Vessels shipped with durable ready-to-bury coating. Vessels, depending on manufacturing location, are either powder coated with phenolic epoxy, painted with a single application urethane coating, or primed with liquid epoxy and coated with liquid epoxy top coat – all providing a durable ready-to-bury coating.

  • All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel.

333-1000UG

More Info

UOM : EA

1000 Gal Above Ground Propane Tank

General Specifications


  • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1.

  • Complies with NFPA 58.

  •  Rated at 250 psig from -20° F to 125° F. All vessels registered with National Board. All standard vessels UL listed (UL 644 – Container Assemblies for LP-Gas). Standard vessels available with CRN (Canadian Registration Number).

  •  Vessels are either powder coated with TGIC polyester or primed with liquid epoxy and coated with liquid urethane top coat.

  •  All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel.

  •  

333-1000AG

More Info

UOM : EA

500 Gal Underground Propane Tank

General Specifications


  • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1.

  • Complies with NFPA 58.

  • Rated at 250 psig from -20° F to 125° F. All vessels registered with National Board. Some standard vessels available with CRN (Canadian Registration Number).

  • Vessels shipped with durable ready-to-bury coating. Vessels, depending on manufacturing location, are either powder coated with phenolic epoxy, painted with a single application urethane coating, or primed with liquid epoxy and coated with liquid epoxy top coat – all providing a durable ready-to-bury coating.

  • All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel.

333-500UG

More Info

UOM : EA

250 Gal Underground Propane Tank

General Specifications


  • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1.

  • Complies with NFPA 58.

  • Rated at 250 psig from -20° F to 125° F. All vessels registered with National Board. Some standard vessels available with CRN (Canadian Registration Number).

  • Vessels shipped with durable ready-to-bury coating. Vessels, depending on manufacturing location, are either powder coated with phenolic epoxy, painted with a single application urethane coating, or primed with liquid epoxy and coated with liquid epoxy top coat – all providing a durable ready-to-bury coating.

  • All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel.

333-250UG

More Info

UOM : EA

500 Gal Above Ground Propane Tank

General Specifications


  • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1.

  • Complies with NFPA 58.

  •  Rated at 250 psig from -20° F to 125° F. All vessels registered with National Board. All standard vessels UL listed (UL 644 – Container Assemblies for LP-Gas). Standard vessels available with CRN (Canadian Registration Number).

  •  Vessels are either powder coated with TGIC polyester or primed with liquid epoxy and coated with liquid urethane top coat.

  •  All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel.

  •  

333-500AG

More Info

UOM : EA

120 Gal Underground Propane Tank

General Specifications


  • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1.

  • Complies with NFPA 58.

  • Rated at 250 psig from -20° F to 125° F. All vessels registered with National Board. Some standard vessels available with CRN (Canadian Registration Number).

  • Vessels shipped with durable ready-to-bury coating. Vessels, depending on manufacturing location, are either powder coated with phenolic epoxy, painted with a single application urethane coating, or primed with liquid epoxy and coated with liquid epoxy top coat – all providing a durable ready-to-bury coating.

  • All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel.

333-120UG

More Info

UOM : EA